Measurement Range:E -200 to 800°C / K -200 to 1370°C
HOLDThe thermometer stops measurement
by the HOLD key and holds the present readings. Auto power-off
The thermometer will turn the power off automatically after 5minutes. Resolution change
Press the 1/0.1 key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Calibration
The displayed value can be adjusted the CAL SET key. Alarm output
The thermometer gives an alarm when readings go beyond the high or low limits.
(Temperature probes not included)
Download catalog
Return to series top pageSpecifications
Model | HD-1350 | ||
Display | LCD with Backlight | ||
Waterproof specifications | - | ||
Input connector | ANP | ||
Input type | Thermocouple Input: Type E, K*1 | ||
Channel | 1ch | ||
Signal source resistance | MAX.500ohm | ||
Measurement Range | 1°C Resolution | E | -200 to 800°C |
K | -200 to 1370°C | ||
0.1°C Resolution | E | -104.9 to 504.9°C (Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) | |
K | -104.9 to 504.9°C (Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) | ||
Measurement Accuracy | 1°C Resolution | 0°C to | ± (0.1% of reading +1°C) |
to 0°C | ± (0.5% of reading +1°C) | ||
0.1°C Resolution | 0°C to | ± (0.05% of reading + 0.2°C) | |
to 0°C | ±0.5°C | ||
Reference junction compensation accuracy | ±0.2°C at 25°C±10°C | ||
Temperature Coefficient | ±0.01% of F/S per °C (F/S : full scale) | ||
Operation Environment | 0 to 40°C, 0 to 80%RH (Non condensing) 32 to 104°F, 0 to 80%RH (Non condensing) | ||
Storage Environment | -20 to 50°C, 0 to 85%RH (Non condensing) -4 to 122°F, 0 to 85%RH (Non condensing) | ||
Battery life | 300h | ||
Power supply(Dry battery) | 4 AA Alkali Batteries | ||
Power supply(AC power) | AC-Adaptor (Option) | ||
Sampling rate | approx.300ms | ||
Linearlizer | Digital Linearizer method (Compliant with IEC 60584-1 (2013)) | ||
Dimensions(mm) | approx. 76(w)×167(H)×36(D) [Protruded parts excluded] | ||
Weight | approx. 350g [Include Batteries] | ||
Supplied accessories | Manual,Test report,Soft case, | ||
Hand strap,4 AA Alkaline batteries | |||
Optional accessories | Alarm output Cable | ||
Alarm Output | (Table1) | ||
Analog Output | - | ||
Compatible standards | CE Marking, RoHS |
*1 Details of typeJ,T,R(option)
Table1 Alarm Output
Output Pattern | Upper Limit | Lower Limit |
More than upper limit | H(5V) | L(0V) |
Between upper and lower limit | L(0V) | L(0V) |
Less than lower limit | L(0V) | H(5V) |
* Signal current of up to 5mA can be taken out.